  • Explain the difference between window width and window level and their clinical use.
  • How does windowing influence image interpretation, and what pitfalls should be avoided?
  • What effect do radiographic grids have on contrast?
  • Which parameter describes the system's ability to record a wide range of brightness levels?
  • What converts light into a charge?
  • How does using a grid affect receptor exposure if mAs is not increased to compensate?
  • Beam restriction reduces the number of Compton interactions, affecting contrast how?
  • How do direct conversion DR detectors differ from indirect conversion DR detectors?
  • What term describes the distance range within which a focused grid can be used?
  • What are common PSP plate artifacts, and how can we mitigate them?
  • What is the fill factor in digital detectors and how does it affect image quality?
  • What is gray-scale mapping, and how can inappropriate mapping mislead diagnosis?
  • A high SNR provides an image with:
  • Which change to exposure setup will increase magnification and potentially reduce spatial resolution?
  • What are the potential consequences of excessive edge enhancement on radiographic images?
  • Why is post-processing used in digital radiography and what safeguards guide its use?
  • Which parameter primarily influences beam energy and radiographic contrast?
  • Excessive processing of the digital image may:
  • Which metric is used to evaluate the spatial resolution performance of a digital radiography system?
  • Which governs the relationship between SID and receptor exposure?
  • What is a histogram in digital radiography, and why is histogram analysis performed after exposure?
  • Explain detector lag and its potential impact on follow-up imaging.
  • Quality assurance of digital imaging requires uniformity of processing codes to ensure what outcome?
  • Which are the primary controlling factors of receptor exposure?
  • The portion of radiographic contrast caused by variations in anatomy or pathology is called?
  • Which grid design provides the best scatter cleanup?
  • The radiographic image is formed by which of the following?
  • Which term describes the range of receptor exposures that provides a quality image?
  • Which parameter controls the number of gray shades per pixel?
  • What is the impact of increasing the amount of processing on image quality?
  • Elongation occurs when the X-ray beam is angled along the long axis of a part.
  • Why might exposure be increased when using a grid in digital radiography?
  • Using a large focal spot will primarily affect image sharpness by:
  • How does focal spot size influence geometric unsharpness and spatial resolution?
  • An indicator of the dose level needed to acquire an optimal image is which metric?
  • Why is it important to track patient dose and maintain dose records for each exam?
  • Smoothing software may result in:
  • Improper use of grids may result in an image artifact known as:
  • Beam-part-receptor alignment latitude describes the latitude of collimation that still allows what?
  • If the pixel density increases, what happens to the detector's ability to resolve small details?
  • Grid ratio is defined as:
  • Which statement describes the effect of using a smaller focal spot on spatial resolution?
  • A primary advantage to digital fluoroscopy is:
  • The space from the center of a pixel to the center of the adjacent pixel is called:
  • How do kVp and mAs collectively influence detector exposure, image contrast, and patient dose?
  • Digital imaging is driven by which factor?
  • Digital image receptors are more sensitive to which factor?
  • The useful image acquisition area of an image receptor is which?
  • Visible differences in adjacent structures on a radiographic image describe:
  • Undesirable fluctuations in image brightness are called?
  • When selecting a grid for digital radiography, which factor should be considered?
  • Nyquist frequency in detector sampling: which statement is correct?
  • mAs directly controls:
  • Bit depth is equal to:
  • How does grid frequency influence the risk of Moiré patterns in digital radiography?
  • Distinguish between aliasing and Moiré; why are they concerns in digital imaging?
  • The variation of x-ray intensity along the longitudinal axis describes which phenomenon?
  • Filtration has little effect on receptor exposure because x-rays removed from beam are not image-producing rays.
  • Elongation and foreshortening are examples of:
  • The available grayscale of an imaging system is determined by which factor?
  • In radiography, high kVp is associated with which statement about grayscale?
  • In indirect conversion DR detectors, X-rays are first converted to what in the scintillator before becoming an electrical signal?
  • In digital radiography, what does bit depth influence?
  • Quality assurance and maintenance of CR cassettes include erasing plates at least:
  • What is the ALARA principle and how does dose tracking support it?
  • The number of pixels per millimeter in an image to the center of the adjacent pixel is called:
  • Compare the CR (PSP) workflow with the DR workflow.
  • Reducing the object-to-image distance (OID) will have what effect on spatial resolution?
  • The smallest resolvable area in a digital imaging device is which?
  • What is the purpose of maintaining dose records for each exam?
  • Why is monitor calibration important in radiology imaging?
  • A radiographic image with few gray tones, primarily black and white, has which type of contrast?
  • Mathematical codes used to generate the digital image are called:
  • Which metric combines dose and irradiated area to quantify the radiation exposure delivered to the patient?
  • Which term describes the highest spatial frequency that can be recorded by a digital detector?
  • The smallest area represented in a digital image is the:
  • What allows more anatomic structures to be captured during an exposure?
  • If you change from a nongrid technique with 10 mAs at 75 kVp to using a 12:1 grid at 75 kVp, what mAs is needed to produce the same image?
  • Which statement about focal-spot size is true according to the material?
  • The anode heel effect results in greater intensity toward which side of the beam?
  • Distortion that occurs when the x-ray beam is angled along the long axis of a part is:
  • Which grid type provides the most effective scatter cleanup?
  • How does pediatric imaging impact technique selection and dose?
  • Which single factor listed will increase spatial resolution?
  • Which term describes the distance between centers of adjacent pixels?
  • The level of kVp that yields more uniform penetration through anatomy is which option?
  • To reduce patient dose, exposure technique in digital imaging should be adjusted by which change?
  • The grid type designed with lead strips and interspacers angled to match beam divergence is called which grid type?
  • Which term describes a high-contrast image with limited gray tones?
  • Which principle states that the product of current and exposure time yields the same receptor exposure if the mAs is the same?
  • What does exposure reproducibility mean in radiography, and how is it ensured?
  • Spatial resolution is defined as which of the following?
  • Dose Area Product is best described as:
  • If the exposure field is not accurately recognized, the histogram will contain data:
  • How are exposure indicators (EI) used to manage dose and image quality?
  • The smallest resolvable detector unit is called which?
  • In general, anything interfering with accurate image formation is known as which term?
  • What is the importance of monitor calibration in radiology imaging?
  • An artificial increase in display contrast at an edge of the image is called which?
  • What is the purpose of using standard presets in post-processing to avoid misrepresentation?
  • The expression of image quality provided by a detector is called:
  • What is the function of quantization in digital imaging?
  • Differential absorption of the x-ray beam is a function of which interaction?
  • The element in the imaging chain that converts light into an electrical signal is the:
  • What is a ghost image, and in which imaging mode is it most commonly a concern?
  • The actual patient dose as measured by a meter embedded in the collimator is:
  • How does geometric unsharpness relate to focal spot size in radiography?
  • Higher fill factor directly improves detection efficiency and signal-to-noise ratio.
  • Nyquist frequency and detector sampling: what is it and why is it relevant?
  • In radiographic geometry, increasing the object-to-image distance (OID) will:
  • The process of assigning a value to each pixel to represent a gray tone is called:
  • Low-kVp technique is most associated with which type of contrast scale?
  • What is dose creep, and how can it be prevented?
  • Thicker part of anatomy should be placed under which aspect of the x-ray tube?
  • What happens when automatic rescaling corrects for underexposure; what is a potential risk?
  • How does patient motion affect image quality, and what strategies reduce motion artifacts?
  • Technique charts: which statement is true?
  • Technique charts are most beneficial when manual techniques are used. Which option reflects this idea?
  • The range of source-to-image distances (SIDs) that may be used with a focused grid is called what?
  • Distortion may be described as:
  • Quantum noise limits ability to see:
  • Grid cutoff may be described as which phenomenon?
  • Low signal-to-noise ratio results in what effect on the image?
  • Using high kVp results in which type of contrast and grayscale?
  • Why is technique documentation important in digital radiography performance and QA?
  • Which material is used in direct conversion DR detectors?
  • Name two common QA tests for DR systems.
  • What is the consequence of poor exposure reproducibility on dose tracking and QA comparisons?
  • As beam filtration increases, image contrast typically changes how?
  • What is the effect of filtration on receptor exposure?
  • GCF is defined as the amount of increase in kVp necessary when converting from nongrid to grid techniques.
  • Define quantum mottle and its relationship to exposure.
  • Increasing beam filtration results in a beam described as harder. Which energy-related description is correct?
  • To maintain receptor exposure when using a grid, you should increase which parameter?
  • When using beam restriction, what adjustment is typically required for technical factors?
  • What is automatic exposure control (AEC), and what is its main benefit?
  • Which factor is most associated with reducing grid-related artifacts?
  • What is exposure latitude, and why do digital systems typically offer wider latitude than film-screen?
  • If SID is reduced by one half, what must be done to mAs to maintain a constant receptor exposure?
  • Grid selectivity is defined as the ratio of primary radiation transmitted through the grid to secondary radiation transmitted through the grid.
  • What is the effect of increasing kVp on subject contrast?
  • Which of the following are primary factors that limit spatial resolution in a digital radiography system?
  • Quality assurance and maintenance of CR cassettes include cleaning and inspecting the plates at least:
  • In digital fluoroscopy, what equipment should be used to view the image?
  • What is the effect of detector uniformity on image quality, and what can nonuniformity cause?
  • What does the Modulation Transfer Function (MTF) describe in radiographic systems?
  • The number of electrons that flow from the cathode to the anode in the tube is controlled by:
  • Lower spatial resolution may be caused by which factor?
  • How does histogram-based exposure evaluation aid technique adjustments after a chest radiograph?
  • How do scatter, beam quality, and patient size interact to affect image contrast?
  • Which statement correctly describes magnification in radiography?
  • Magnification is caused by:
  • What is DICOM, and why is it essential in digital radiography?
  • If histogram indicates underexposure, which adjustments are typically considered?
  • Which artifact is least likely to be seen on a PSP plate?
  • How does the appearance of digital images on technologists' monitors compare with radiologists' monitors?
  • Energy of the x-ray photons produced is primarily determined by:
  • In digital images, what term describes the smallest unit of an image file that stores brightness information?
  • What is the role of collimation in dose management and image quality?
  • Receptor exposure may be defined as which of the following?
  • Contrast improvement factor is the measure of the grid's ability to enhance contrast.
  • What is the Moiré effect, and how can it be prevented in grid-based radiography?
  • The grid type with lead strips and aluminum interspacers angled to coincide with the divergence of the x-ray beam is called what?
  • In digital radiography, what is the effect of higher detector sampling frequency on spatial resolution?
  • Define detective quantum efficiency (DQE) and its impact on dose efficiency.
  • If SID is doubled, what may be said about receptor exposure?
  • Which term is synonymous with the range of receptor exposures that yields diagnostic image quality?
  • How can the use of a technique chart reduce dose creep in a DR program?
  • How do grids influence image quality and patient dose in modern digital radiography?
  • What is the role of QA in DR system maintenance and what are typical frequencies?
  • Why is mAs still a clinically important parameter in digital radiography?
  • What is the Last Image Hold feature and its clinical use?
  • What is detector saturation, and why is it undesirable?
  • In CR imaging, what term describes the plate that stores the latent image?
  • Which device is used to physically restrict the size and shape of the x-ray beam?
  • As beam restriction tightens, receptor exposure what happens to receptor exposure?
  • Which component of a digital detector is responsible for producing light after absorbing X-rays?
  • The active portion(s) of a CR IP is (are):
  • Why is dose optimization essential in digital radiography despite wide detector latitude?
  • What is edge enhancement and when can it cause diagnostic errors?
  • Given an original technique of 30 mAs and 80 kVp, which would produce an image with double the receptor exposure?
  • Which statement describes the effect of beam restriction on radiographic contrast?
  • Which of the following factors does NOT contribute to degraded spatial resolution?
  • Which term describes image distortion that mimics misrepresentation of an anatomic structure on the radiograph?
  • A material that absorbs x-ray energy and emits part of that energy as visible light is called:
  • Which of the following maintains image brightness over a wide range of exposures?
  • Digital image receptors are more sensitive to which factor?
  • What is the primary mechanism by which grids improve image contrast?
  • What is the impact of prosthetic materials on digital image acquisition, and how is it managed?
  • What does flat-field calibration accomplish in detector uniformity?
  • Which software function is used to bring uniform brightness across the image by smoothing?
  • Define bit depth and its effect on grayscale resolution.
  • What is the software function that evens the brightness displayed in the image called?
  • Distortion that occurs when the x-ray beam is angled against the long axis of a part is:
  • The CR reader unit scans the IP with a which device?
  • Which of the following is a correct pairing of artifact/phenomenon and its associated cause?
  • What is the primary purpose of grids?
  • What is a practical measure to prevent Moiré patterns in DR imaging?
  • Which of the following best describes the goal of uniform processing codes in digital imaging quality assurance?
  • Which graphical representation displays the distribution of pixel values in an image?
  • Gross overexposure of the IR results in:
  • Beam-part-receptor alignment latitude describes which concept?
  • In digital radiography, what is the practical implication of wide detector latitude for exposure management?
  • Which statement about the air gap technique is true?
  • When AEC is used, increasing the kVp has which effect?
  • Which of the following affects receptor exposure?
  • Which dose metric is commonly included in DR dose tracking?
  • The relationship between kVp and receptor exposure is best described as
  • The primary controlling factor(s) of contrast is (are):
  • How can exposure index values vary among manufacturers, and why is this important?
  • The number of pixels making up the digital image is described by which term?
  • If kVp is increased by 15% with the mAs unchanged, receptor exposure will approximately:
  • Grid cutoff is most clearly described as which of the following?
  • The function of contrast is to:
  • Why must DICOM header information be accurate and complete?
  • Receptor exposure was formerly called:
  • In digital radiography inappropriate collimation can cause which of the following?
  • To reduce patient dose, digital imaging technique should be adjusted by increasing kVp. Which option best represents this guidance?
  • Optimal spatial resolution may be created using which of the following factors?
  • Which statement about the role of kVp is accurate?
  • Exposure indicators provide a numeric measure of detector exposure; consistent EI helps maintain uniform brightness.
  • The 15% rule states that:
  • Grid frequency is defined as:
  • How is dose tracking integrated into digital radiography systems?